Burners and Nozzle Specifications
Table 1
Liquid Gas Natural Gas
Burner Diameter
(mm)
Thermal power
kW (p.c.s.*)
By-Pass
1/100
Nozzle
1/100
Flow*
g/h
Nozzle
1/100
Flow*
l/h
Nomin. Ridot. (mm) (mm) *** ** (mm)
Fast (R) 100 3,00 0,70 41 86 218 214 116 286
Semi Fast (S) 75 1,90 0,40 30 70 138 136 106 181
Auxiliary (A) 55 1,00 0,40 30 50 73 71 79 95
Supply
Pressures
Nominal (mbar)
Minimum (mbar)
Maximum (mbar)
28-30
20
35
37
25
45
20
17
25
** At 15°C and 1013 mbar-dry gas
** Propane P.C.S. = 50.37 MJ/kg.
*** Butane P.C.S. = 49.47 MJ/kg.
Natural P.C.S. = 37.78 MJ/m
3
Electrical Connection
Gas Section:Class II2H3+
Rated Power kW (1) 7,8 (567gr/h-G30)
(557gr/h-G31)
(1) Values in g/h refer to capacities with liquid
gas (Butane, Propane).
Electrical connection
The electrical connection to the mains must be made on the
appliance. The power voltage and frequency are as
indicated on the rating plate.
WARNING: THIS APPLIANCE MUST BE EARTHED.
CONNECTING TO A 230-240V 50Hz SUPPLY ONLY.
The electrical installation should be carried out in compliance
with the current electricity regulations by a qualified electrician.
The cable should be routed so that it does not come into
contact with the hob base by securing it to the cabinet side
or rear wall.
It should be connected to a suitable double pole isolating
switch having a contact separation of at least 3mm in all
poles placed in a readily accessible position adjacent to the
hob.
IMPORTANT:
The wires in the mains lead fitted to this appliance are
coloured in accordance with the following code:
GREEN - EARTH
BLUE - NEUTRAL
BROWN - LIVE
It is the law that all gas appliances are installed by competent persons in accordance with the currect edition of the Gas
Safety (Installation and Use) Regulations. It is in your interest and that of safety to ensure compliance with the law.
In the UK, CORGI registered installers work to a safe standard of practice.
The hob must be installed in accordance with BS6172:
Failure to install the hob correctly could invalidate the warranty liability claims and could lead to prosecution.