Installation Instructions
4
ELECTRICAL CONNECTION
INFORMATION
ELECTRICAL REQUIREMENTS
This appliance must be supplied with 120V, 60Hz, and
connected to a properly grounded branch circuit,
protected by a 15- or 20- amp circuit breaker or time-
delay fuse. If electrical supply provided does not meet the
DERYH VSHFL¿FDWLRQV LW LV UHFRPPHQGHG WKDW D OLFHQVHG
electrician install an approved outlet.
:$51,1*TO REDUCE THE
5,6.2)),5((/(&75,&$/6+2&.
AND PERSONAL INJURY:
'212786($1(;7(16,21&25'25$1$'$37(5
3/8*:,7+7+,6$33/,$1&(
Dryer must be electrically grounded in accordance
with local codes and ordinances, or in the absence
of local codes, in accordance with the NATIONAL
ELECTRICAL CODE, ANSI/NFPA NO. 70.
:$51,1* THIS DRYER IS
(48,33(' $ 7+5((3521* *5281',1*
PLUG FOR YOUR PROTECTION AGAINST
6+2&.+$=$5'$1'6+28/'%(3/8**('
DIRECTLY INTO A PROPERLY GROUNDED
7+5((3521* 5(&(37$&/( '2 127 &87
25 5(029( 7+( *5281',1* 3521*
)5207+,63/8*
ENSURE PROPER GROUND
EXISTS BEFORE USE.
IF LOCAL CODES PERMIT,
AN EXTERNAL GROUND WIRE
(NOT PROVIDED), WHICH MEETS
LOCAL CODES, MAY BE ADDED
BY ATTACHING TO THE GREEN
GROUND SCREW ON THE REAR
OF THE DRYER, AND TO A GROUNDED
METAL COLD WATER PIPE OR OTHER
ESTABLISHED GROUND.
(;+$867,1)250$7,21
:$51,1* IN CANADA AND IN THE
81,7('67$7(67+(5(48,5('(;+$867'8&7
',$0(7(5,6,1PP'212786('8&7
/21*(57+$163(&,),(',17+((;+$867
/(1*7+7$%/(
8VLQJH[KDXVWORQJHUWKDQVSHFL¿HGOHQJWKZLOO
• Increase the drying times and the energy cost.
• Reduce the dryer life.
$FFXPXODWHOLQWFUHDWLQJDSRWHQWLDO¿UHKD]DUG
7KHFRUUHFWH[KDXVWLQVWDOODWLRQLVYOUR
RESPONSIBILITY3UREOHPVGXHWRLQFRUUHFWLQVWDOODWLRQ
DUHQRWFRYHUHGE\WKHZDUUDQW\
Remove and discard existing plastic or metal foil transition
duct and replace with UL listed transition duct.
The 0$;,080$//2:$%/( duct length and number of
bends of the exhaust system depends upon the type of
duct, number of turns, the type of exhaust hood (wall cap),
and all conditions noted below. The maximum duct length
for rigid metal duct is shown in the table below.
EXHAUST LENGTH
4" DIA.
4"
4" DIA.
4" DIA.
2-1/2"
RECOMMENDED MAXIMUM LENGTH
Exhaust Hood Types
Recommended
No. of 90º
Elbows
Rigid
Metal
Rigid
Metal
90 Feet
60 Feet
45 Feet
35 Feet
0
1
2
3
60 Feet
45 Feet
35 Feet
25 Feet
Use only
for short
run installations
(;+$8676<67(0&+(&./,67
HOOD OR WALL CAP
Terminate in a manner to prevent back drafts or entry of birds or
other wildlife.
Termination should present minimal resistance to the exhaust air
ÀRZDQGVKRXOGUHTXLUHOLWWOHRUQRPDLQWHQDQFHWRSUHYHQWFORJJLQJ
1HYHU install a screen in or over the exhaust duct. This could cause
lint build up.
Wall caps must be installed at least 12 in. above ground level or any
other obstruction with the opening pointed down.
SEPARATION OF TURNS
For best performance, separate all turns by at least 4 ft. of straight
duct, including distance between last turn and exhaust hood.
TURNS OTHER THAN 90º
• One turn of 45º or less may be ignored.
• Two 45º turns should be treated as one 90º turn.
• Each turn over 45º should be treated as one 90º turn.
SEALING OF JOINTS
All joints should be tight to avoid leaks. The male end of each section
of duct must point away from the dryer.
Do not assemble the ductwork with fasteners that extend into the
duct. They will serve as a collection point for lint.
Duct joints can be made air and moisture-tight by wrapping the
overlapped joints with duct tape.
Horizontal runs should slope down toward the outdoors 1/4
inch per foot.
INSULATION
Duct work that runs through an unheated area or is near air
conditioning should be insulated to reduce condensation and lint
build-up.
For every extra 90° elbow, reduce the allowable vent system
length by 10 ft.
Two 45° elbows will be treated like one 90° elbow.
For the side exhaust installations, add one 90° elbow to the
chart.
The total vent system length includes all the straight portions
and elbows of the system (transition duct included).