Hotpoint HAG60P Operations Instructions Page 5

  • Download
  • Add to my manuals
  • Print
  • Page
    / 28
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 4
5
GB
PLEASE PHONE US TO REGISTER YOUR APPLIANCE AND ACTIVATE YOUR PARTS GUARANTEE ON 08448 24 24 24
Installation
Prior to installation, ensure that the local distribution
conditions (nature of the gas and gas pressure)
and the adjustment conditions are compatible. The
adjustment conditions for this appliance are stated on
the data badge which is fitted on the back panel.
This appliance is not designed to be connected to a
combustion products evacuation device. It must be
installed and connected in accordance with current
installation regulations. particular attention should
be given to the relevant requirements regarding
ventilation.
MODEL NUMBERS HAG 60
Category II2H3+ (GB)
These models are set to burn NATURAL GAS (G20)
at 20 mbar but can be converted for use on BUTANE
(G30) at 28-30mbar with the use of the LPG conversion
kit that can be obtained free of charge, if you contact
our Genuine Parts and Accessories department (see
Key Contacts, back page).
GAS SAFETY (INSTALLATION & USE)
REGULATIONS
It is the law that all gas appliances are installed by
competent persons in accordance with the current
edition of the above regulations. It is in your interest
and that of safety to ensure compliance with the
law. In the UK, CORGI registered installers work to
safe standards of practice. The cooker must also be
installed in accordance with BS 6172. Failure to install
the cooker correctly could invalidate the warranty
liability claims and could lead to prosecution.
Adapting to different types of gas
(main and top oven)
In order to adapt the oven to a different type of gas
with respect to the gas for which it was manufactured
(indicated on the label), follow these simple steps:
a) Replacing the oven burner nozzle
open the oven door fully
pull out the sliding oven bottom
V
V
Z
Pry the fixing tab "V" and remove the oven burner
Unscrew the oven burner nozzle using the socket
spanner for the nozzles "Z", or a 7 mm socket
spanner, and replace it with a nozzle suited to the
new type of gas (see Table). Take particular care
handling the spark plug wires and the thermocou-
ple pipes.
Replace all the parts, following the steps described
above in the reverse order.
G20 at 20mbar
G30 at 28-30mbar
G31 at 37mbar
Burner
Heat Input Injector Heat Input Injector
Hotplate
Front Left and Rear Right
3.0 kW 116 3.0 kW (220g/h) 86
Hotplate
Front Right and Rear Left
2.0 kW 103 2.0 kW (145g/h) 70
Grill 3.7 kW 150 (X) 3.4 kW (246g/h) 91
Main Oven 2.5 kW 115 2.3 kW (166g/h) 71
Top Oven 1.9 kW 100 1.9 kW (136g/h) 66
Page view 4
1 2 3 4 5 6 7 8 9 10 ... 27 28

Comments to this Manuals

No comments